Mermade Filter's modulating float valve rendering shown against a grey background

The resistance to flow between these two opening positions establishes the minimum depth required for the center of the main drain line so that the desired flow can be maintained. If the depth and size of the line are incorrect the proper flow rate will not be attainable. At full closed, the valve will flow at approximately 20% of the maximum water velocity. Maximum flow in a suction line is normally 6 feet per second of water velocity. Mer-Made offers two different styles of float valves. The basic float valve is the disc configuration (FV) which can be fitted with an elbow or "T". The elbow directs the flow below the water level to minimize the turbulence and the associated generation of chlorine fumes. The "T" configuration allows the pool to be pumped out via the main drain line. A manual valve must be mounted on the "T" leg which can be closed from the deck (long shaft on the handle) to allow pump suction on the pipe from the main drain. This configuration requires the use of the XWB modification.

POOL SURGE TANK VALVE

Modulating (float) valves are not tight-closing, in fact, our valves are designed to pass some flow when the ball is in the full up or “closed” position, so as not to stop main drain flow entirely. The optimum operating condition for the float controlled valve is between 60% and 70% open. The resistance to flow between these two opening positions establishes the minimum depth required for the center of the main drain line so that the desired flow can be maintained. If the depth and size of the line are incorrect the proper flow rate will not be attainable. See table #1 for values of depth versus flow. Use the charts given to select a valve and minimum depth needed to achieve the flow rate for the pool turnover you require. Note that the depth from the chart is not all that is required. To this depth you must add an estimate of the losses in the main drain line before the valve. The valve tables are limited to a maximum water velocity of six feet per second. This velocity will generally give line losses which are much smaller than the losses through the modulating valve.

this is a graph that charts the percent open vs. the depth below the pool water level for mermade filter modulating float valves
Title Size
Mer-Made Filter Modulating Float Valves Brochure 528.66kB Preview Download
Title Size
Mermade Filter Modulating Float Valves Charts and Data Sheets 923.80kB Preview Download
Top